Hydraulic Pile Hammer Specification

MODEL NAME MEANING: EX) SGH-3012 (30: RAM WEIGHT, 12: 1.2M STROKE)

BRUCE HYDRAULIC PILE HAMMER MODEL

MODEL NAME MEANING: EX) SGH-3012 (30: RAM WEIGHT, 12: 1.2M STROKE)

Ram Weight 2 ton 4409 lbs
Min. Stroke 200 mm 0.66 ft
Max. Stroke 1200 mm 3.94 ft
Max. Potential Energy 2.4 ton.m 24 kN.m
Blow Rate at Max, Stroke 40 bpm 40 bpm
Operating Pressure 230 bar 3,337 psi
Required Flow Rate 100 lpm 27 gpm
Suitable Excavator 24 tons 24 ton
Ram Weight3 ton6614 lbs
Min. Stroke200 mm0.66 ft
Max. Stroke1200 mm3.94 ft
Max. Potential Energy3.6 ton.m35 kN.m
Blow Rate at Max, Stroke40 bpm40 bpm
Operating Pressure230 bar3,337 psi
Required Flow Rate100 lpm27 gpm
Suitable Excavator24 tons24 tons
Ram Weight 3 ton 6614 lbs
Min. Stroke 200 mm 0.66 ft
Max. Stroke 1500 mm 4.92 ft
Max. Potential Energy 4.5 ton.m 44 kN.m
Blow Rate at Max, Stroke 36 bpm 36 bpm
Operating Pressure 230 bar 3,337 psi
Required Flow Rate 100 lpm 27 gpm
Suitable Excavator 24 tons 24 tons
Ram Weight 4 ton 8819 lbs
Min. Stroke 200 mm 7.87 ft
Max. Stroke 1200 mm 3.94 ft
Max. Potential Energy 4.8 ton.m 47 kN.m
Blow Rate at Max, Stroke 40 bpm 40 bpm
Operating Pressure 230 bar 3,337 psi
Required Flow Rate 123 lpm 33 gpm
Suitable Power Pack PQ-150 PQ-150
Ram Weight4 ton8819 lbs
Min. Stroke200 mm0.66 ft
Max. Stroke1200 mm3.94 ft
Max. Potential Energy4.8 ton.m47.1 kN.m
Blow Rate at Max, Stroke40 bpm40 bpm
Operating Pressure230 bar3,337 psi
Required Flow Rate123 lpm33 gpm
Suitable Power PackPQ-150PQ-150
Ram Weight5 ton11023 lbs
Min. Stroke200 mm0.66 ft
Max. Stroke1200 mm3.94 ft
Max. Potential Energy6 ton.m59 kN.m
Blow Rate at Max, Stroke40 bpm40 bpm
Operating Pressure230 bar3,337 psi
Required Flow Rate190 lpm50 gpm
Suitable Power PackPQ-250PQ-200
 Ram Weight 7 ton15432 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 8.4 ton.m83 kN.m
 Blow Rate at Max, Stroke 40 bpm40 bpm
 Operating Pressure 230 bar3,337 psi
 Required Flow Rate 190 lpm50 gpm
 Suitable Power Pack PQ-200PQ-200
 Ram Weight 7 ton15432 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 10.5 ton.m103kN.m
 Blow Rate at Max, Stroke 60 bpm60 bpm
 Operating Pressure 230 bar3,337 psi
 Required Flow Rate 230 lpm61 gpm
 Suitable Power Pack PQ-250PQ-250
 Ram Weight 10 ton22046 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 12 ton.m118 kN.m
 Blow Rate at Max, Stroke 38 bpm38 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 260 lpm69 gpm
 Suitable Power Pack PQ-250PQ-250
 Ram Weight 10 ton22046 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 15 ton.m147 kN.m
 Blow Rate at Max, Stroke 35 bpm35 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 296 lpm78 gpm
 Suitable Power Pack PQ-250PQ-250
Ram Weight 12 ton 26455 lbs
Min. Stroke 200 mm 0.66 ft
Max. Stroke 1200 mm 3.94 ft
Max. Potential Energy 14.4 ton.m 141 kN.m
Blow Rate at Max, Stroke 38 bpm 38 bpm
Operating Pressure 250 bar 3,627 psi
Required Flow Rate 320 lpm 85 gpm
Suitable Power Pack PQ-250 PQ-250
 Ram Weight 12 ton26455 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 18 ton.m177 kN.m
 Blow Rate at Max, Stroke 38 bpm38 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 370 lpm98 gpm
 Suitable Power Pack PQ-250PQ-250
 Ram Weight 13 ton28659 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 15.6 ton.m153 kN.m
 Blow Rate at Max, Stroke 35 bpm35 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 320 lpm85 gpm
 Suitable Power Pack PQ-250PQ-250
Ram Weight13ton28659 lbs
Min. Stroke200 mm0.66 ft
Max. Stroke1500 mm4.92 ft
Max. Potential Energy19.5 ton.m191 kN.m
Blow Rate at Max, Stroke35 bpm35 bpm
Operating Pressure250 bar3,627 psi
Required Flow Rate370 lpm98 gpm
Suitable Power PackPQ-400PQ-400
 Ram Weight 14 ton30865 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 16.8 ton.m165kN.m
 Blow Rate at Max, Stroke 36 bpm36 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 320 lpm85 gpm
 Suitable Power Pack PQ-250PQ-250
 Ram Weight 14 ton30865 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 21 ton.m206 kN.m
 Blow Rate at Max, Stroke 35 bpm35 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 370 lpm98 gpm
 Suitable Power Pack PQ-250PQ-250
 Ram Weight 16 ton35274 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 19.2 ton.m188 kN.m
 Blow Rate at Max, Stroke 32 bpm32 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 350 lpm93 gpm
 Suitable Power Pack PQ-300PQ-300
 Ram Weight 16 ton35274 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm3.94 ft
 Max. Potential Energy 24 ton.m236 kN.m
 Blow Rate at Max, Stroke 30 bpm30 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 410 lpm108 gpm
 Suitable Power Pack PQ-400PQ-400
 Ram Weight 16 ton35274 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1800 mm5.90 ft
 Max. Potential Energy 28.8 ton.m283 kN.m
 Blow Rate at Max, Stroke 28 bpm28 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 480 lpm127 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 16 ton35274 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1900 mm6.53 ft
 Max. Potential Energy 30.4 ton.m298 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 480 lpm127 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 18 ton39683 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 21.6 ton.m212 kN.m
 Blow Rate at Max, Stroke 30 bpm30 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 410 lpm108 gpm
 Suitable Power Pack PQ-400PQ-400
 Ram Weight 18 ton39683 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 27 ton.m265 kN.m
 Blow Rate at Max, Stroke 28 bpm28 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 450 lpm119 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 20 ton44092 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm9.94 ft
 Max. Potential Energy 24 ton.m236 kN.m
 Blow Rate at Max, Stroke 30 bpm30 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 410 lpm108 gpm
 Suitable Power Pack PQ-400PQ-400
 Ram Weight 20 ton44092 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 30 ton.m294 kN.m
 Blow Rate at Max, Stroke 28 bpm30 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 480 lpm127 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 23 ton50706 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 34.5 ton.m338 kN.m
 Blow Rate at Max, Stroke 28 bpm30 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 480 lpm127 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 25 ton55116 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 30 ton.m294 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 600 lpm160 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 25 ton55116 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 37.5 ton.m368 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 650 lpm172 gpm
 Suitable Power Pack PQ-600PQ-600
 Ram Weight 28 ton55116 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 37.5 ton.m368 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 650 lpm172 gpm
 Suitable Power Pack PQ-600PQ-600
 Ram Weight 30 ton66139 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 36 ton.m353 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 600 lpm160 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 30 ton66139 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1300 mm4.27 ft
 Max. Potential Energy 39 ton.m383 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 600 lpm160 gpm
 Suitable Power Pack PQ-500PQ-500
 Ram Weight 30 ton66139 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 45 ton.m441 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 600 lpm160 gpm
 Suitable Power Pack PQ-600PQ-600
 Ram Weight 35 ton77162 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 52.5 ton.m515 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 800 lpm211 gpm
 Suitable Power Pack PQ-700PQ-700
 Ram Weight 40 ton88185 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 48 ton.m470 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 683 lpm206 gpm
 Suitable Power Pack PQ-600PQ-600
 Ram Weight 40 ton88185 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 60 ton.m588 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 650 lpm172 gpm
 Suitable Power Pack PQ-600PQ-600
 Ram Weight 40 ton88185 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1900 mm4.92 ft
 Max. Potential Energy 76 ton.m744 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 650 lpm172 gpm
 Suitable Power Pack PQ-600PQ-600
 Ram Weight 42 ton92594 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 50.4 ton.m494 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 683 lpm211 gpm
 Suitable Power Pack PQ-700PQ-700
 Ram Weight 42 ton92594 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 63 ton.m618 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 854 lpm248 gpm
 Suitable Power Pack PQ-700PQ-700
 Ram Weight 45 ton99208 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 54 ton.m529 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 830 lpm219 gpm
 Suitable Power Pack PQ-700PQ-700
 Ram Weight 45 ton99208 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 67.5 ton.m662 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 1040 lpm275 gpm
 Suitable Power Pack PQ-800PQ-800
 Ram Weight 45 ton99208 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1900 mm6.23 ft
 Max. Potential Energy 85.5 ton.m838 kN.m
 Blow Rate at Max, Stroke 24 bpm24 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 1230 lpm325 gpm
 Suitable Power Pack PQ-1000PQ-1000
 Ram Weight 47 ton103617 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1200 mm3.94 ft
 Max. Potential Energy 56.4 ton.m553 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 830 lpm219 gpm
 Suitable Power Pack PQ-800PQ-800
 Ram Weight 47 ton103617 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1900 mm6.23 ft
 Max. Potential Energy 89.3 ton.m875 kN.m
 Blow Rate at Max, Stroke 24 bpm24 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 1230 lpm325 gpm
 Suitable Power Pack PQ-1000PQ-1000
 Ram Weight 50 ton103617 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1900 mm6.23 ft
 Max. Potential Energy 89.3 ton.m875 kN.m
 Blow Rate at Max, Stroke 24 bpm24 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 1230 lpm325 gpm
 Suitable Power Pack PQ-1000PQ-1000
 Ram Weight 57 ton125664 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 85.5 ton.m839 kN.m
 Blow Rate at Max, Stroke 26 bpm26 bpm
 Operating Pressure 270 bar3,917 psi
 Required Flow Rate 1250 lpm330 gpm
 Suitable Power Pack PQ-1200PQ-1200
 Ram Weight 60 ton132277 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 90 ton.m883 kN.m
 Blow Rate at Max, Stroke 24 bpm24 bpm
 Operating Pressure 250 bar3,556 psi
 Required Flow Rate 1250 lpm330 gpm
 Suitable Power Pack PQ-1200PQ-1200
 Ram Weight 70 ton154324 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 105 ton.m1030 kN.m
 Blow Rate at Max, Stroke 24 bpm24 bpm
 Operating Pressure 250 bar3,556 psi
 Required Flow Rate 1975 lpm522 gpm
 Suitable Power Pack PQ-1500PQ-1500
 Ram Weight 80 ton176370 lbs
 Min. Stroke 200 mm0.66 ft
 Max. Stroke 1500 mm4.92 ft
 Max. Potential Energy 120 ton.m1178 kN.m
 Blow Rate at Max, Stroke 24 bpm24 bpm
 Operating Pressure 250 bar3,556 psi
 Required Flow Rate 1975 lpm522 gpm
 Suitable Power Pack PQ-1500PQ-1500
 Ram Weight 120 ton264555 lbs
 Min. Stroke 200 mm7.87 ft
 Max. Stroke 1600 mm5.25 ft
 Max. Potential Energy 192 ton.m1883 kN.m
 Blow Rate at Max, Stroke 21 bpm21 bpm
 Operating Pressure 250 bar3,627 psi
 Required Flow Rate 2374 lpm627 gpm
 Suitable Power Pack PQ-2000PQ-2000

 

OUTSTANDING FEATURES OF BRUCE PILE HAMMER

with Bruce hammer remote control system, user can control piling and failure check in piling Rig cabin or long distance of piling area. Abnormalities in each function are monitored on LED with high brightness signal so that diagnosis and remedy can be done quickly.

ELECTRIC REMOTE CONTROL SYSTEM FOR ADJUSTING IMPACT ENERGY

control-box-bruce-
with the help of efficient design of hammer body and the cushion arrangement, impact energy from ram drop can be transferred to pile head with lower energy loss. That means the job efficiency can be maximized.

PROMINENT ENERGY TRANSFERRING RATE

bruce-hammer-DSC03600
Compensation of energy drop efficiency during ram drop is functioning by equipped accumulator back charging system to cylinder.

HIGH ENERGY EFFICIENCY & ENERGY TRANSFERRING EFFICIENCY

hydraulic-pile-hammer-piling-hammer-bruce-sgh-1815-6789023-(19)
The well-built structure of hammer cap housing and optimum choice of cushion material ensure longer term use of cushion parts. Therefore customers can achieve the economical operation with lower running cost.

LONGER LIFE TIME OF CUSHION PARTS INCLUDING BUFFER-RINGS

BRUCE-Cushion
The elaborate design of ram parts and its housing enables the ram to travel minimizing the shock on whole hammer structure and cylinder parts as well. This fact gives improved stability of hammer operation.

IMPROVED STABILITY AT RAM MOVEMENT

bruce-pile-hammer-structure-1
Bruce hydraulic hammers are designed and manufactured for long life service with minimal downtime. For the purpose, accurate and precise workmanship are adopted to electric and hydraulic system ensuring low downtime on both systems and promoted endurance with hoses, cables, couplings and other related parts.

LONG-TERM RELIABILITY

hydraulic-pile-hammer-Bruce-SGH-0512-hydraulic-impact-pile-hammer-Lavna-terminal
Bruce hammer can drive all types of piles on leader or crane suspension and can accept drive cap inserts for most types and sizes of piles. Bruce hammer also controls the stroke precisely to match hammer energy helping prevent pile damage and pile runaway.

VERSATILITY AND CONTROLABILITY

piling-hammer-offshore-pile-hammer-bruce-sgh-4519-8890901-(8)
Fixed Leader Type (Round Shape and Square Type), Crane Suspended Type, Offshore Leader Type, U-Type Leads and others can be adaptable.

VARIOUS HAMMER MOUNTING TYPE

hydraulic-pile-hammer-piling-equipment

ENVIRONMENTALY FRIENDLY CONCERN

Bio-degradable hydraulic oil and low emission engine are provided concerning for earth environmental clean.
hydraulic-pile-hammer-power-pack-pq-500-122605-(3)

IMPACT ENERGY MONITORING SYSTEM (IEA SYSTEM) – OPTIONAL

To meet the demand for precise piling nowadays, Bruce hammer provides energy monitoring system as an optional kit, which enables continuous record of each blow energy on real time basis. Hard print and PC link are available for recording and further analysis.
iea-bruce-Accessories-02

VARIOUS KIND OF PILE DRIVING POSSIBILITY

hydraulic-pile-hammer-Bruce-SGH-0512-hydraulic-impact-pile-hammer-06709
Concrete pile (round shape, square shape and octagonal shape), steel casing pile, H-Beam, sheet pile driving is most frequent pile driving way with Bruce hammer.

VISIBLE RAM HEIGHT MOVEMENT

Ram drop height indicator on the side of the hammer is standard equipped with height marking so that operator can see ram drop height easily during pile driving and can adjust ram height stroke during pile driving through remote control box provided.
piling-hammer-offshore-pile-hammer-bruce-sgh-4519-8890901-(9)

HIGH BLOW RATE & PRECISE RAM STROKE MOVEMENT ABILITY

High blow rate is effective to fast pile driving and Bruce remote control system is functioning and controlling stable ram stroke and accuracy pile driving works which is very important without failure of pile driving due to sudden unstable ram height movement. In case of soft driving condition, small pitching pile driving is controlled so that preventing from sudden pile drop to the ground thus suspended crane or piling rig is safe.
bruce-pile-hammerDSC02028

NEW CONCEPTUAL DESIGN OF A SILENCE CAP HOUSING & KIT - OPTIONAL

We put a new conceptual design of a Silence Cap Housing instead of an existing cap housing on the Bruce hammers can be equipped to reduce the noise emissions considerably. There are sound-absorbing materials which called Noise Insulation in it and it surrounds the Drive Cap to make less noise occurrence from a hard hit to obtain a better result, a piece of MC 904 cushion is used as a cushion material.
Accessories-08
Contact Us